TRANSMIT/MONITOR SWITCH CONVERSION KIT
When the optional split-bar Transmit/Monitor Switch Conver-
sion Kit is installed, the Monitor bar must be depressed before
the Transmit switch can be depressed, requiring the operator
to verify that the channel is open before transmitting. The
Monitor bar can be locked in the “on” position. The Transmit
bar is momentary and cannot be locked.
NOTE: Transceiver wiring information must be obtained from
the transceiver schematic and/or the manufacturer.
SPECIFICATIONS
Type
Dynamic
Frequency Response
200 to 5,000 Hz (see Figure 2)
TYPICAL FREQUENCY RESPONSE
FIGURE 2
Polar Pattern
Omnidirectional
Impedance (at 1,000 Hz)
High Impedance: 30,000
Low Impedance: 225
Recommended Load Impedance
High Impedance: 100,000
Low Impedance: 1,000
Output Level (at 1,000 Hz, Open Circuit Voltage)
High Impedance Low Impedance
–35.0 dBV/Pa* –57.0 dBV/Pa*
(17.8 mV) (1.4 mV)
*1 Pa = 94 dB SPL
Switches
Locking Press-to-Talk Switch: Activates microphone cir-
cuit and an external relay or control circuit. The micro-
phone circuit is normally shorted.
Impedance Selection Switch: Double-pole, double-throw
slide switch located in the base of the microphone.
Cable
2.1 m (7 ft.) four-conductor, two conductors shielded,
non-detachable
Case
Two-tone gray ARMO-DUR
R
OVERALL DIMENSIONS
FIGURE 3
Net Weight
737 grams (1 lb., 10 oz.)
Shipping Weight
1020 grams (2 lb., 4 oz.)
Certification
Conforms to European Union directives, eligible to bear
CE marking; meets European Union EMC Immunity Re-
quirements (EN 50082–1, 1992).
REPLACEMENT PARTS
Cartridge R96. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable C31C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
On/Off Switch RK141S. . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONAL ACCESSORIES
Transmit/Monitor Split-Bar Switch Kit RK199S. . . . . . . .
SHURE Incorporated http://www.shure.com
United States, Canada, Latin America, Caribbean:
5800 W. Touhy Avenue, Niles, IL 60714-4608, U.S.A.
Phone: 847-600-2000 U.S. Fax: 847-600-1212 Intl Fax: 847-600-6446
Europe, Middle East, Africa:
Shure Europe GmbH, Phone: 49-7131-72140 Fax: 49-7131-721414
Asia, Pacific:
Shure Asia Limited, Phone: 852-2893-4290 Fax: 852-2893-4055
Page view 1
1 2

Comments to this Manuals

No comments