Shure M367 User's Guide Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 10
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
10
APPENDIX
Changing Limiter Threshold Presets: Samples Calculations
For the following limiter thresholds:
DIP Switch S701
Limiter Threshold R
equiv
Position 2 Position 3 dBm
up up high 12 105 k=R1
down up med. high 8 62 k=R2
up down med. low 4 35 k=R3
down down low 0 18 k=R4
1. Obtain a 105 kΩ, 1/4 Ω, 1% resistor and solder it to the holes of X732.
2.
1
1
1
105,000
R
5
=
= 151.4 k
62,000
Obtain a 150 kΩ, 1/4 W, 1% resistor and solder it to the holes of X733.
3.
= 52.5 k
1
1
1
R
6
=
35,000
105,000
Obtain a 52.3 kΩ, 1/4 W, 1% resistor and solder it to the holes of X734.
4.
1
11
= 49.4 kR
7
=
1
150,000
1
52,30018,000
105,000
Obtain a 49.9 kΩ, 1/4 W, 1% resistor and solder it to the holes of X735.
SHURE Incorporated Web Address: http://www.shure.com
222 Hartrey Avenue, Evanston, IL 60202–3696, U.S.A.
Phone: 847-866–2200 Fax: 847-866-2279
In Europe, Phone: 49-7131-72140 Fax: 49-7131-721414
In Asia, Phone: 852-2893-4290 Fax: 852-2893-4055
Elsewhere, Phone: 847-866–2200 Fax: 847-866-2585
Page view 9
1 2 3 4 5 6 7 8 9 10

Comments to this Manuals